Note: This documentation refers to the PRTG System Administrator user accessing the Ajax interface on a master node. For other user accounts, interfaces, or nodes, not all of the options might be visible in the way described here. When using a cluster installation, failover nodes are read-only by default.

To add a sensor manually, select Sensors | Add Sensor from the main menu. Then an assistant will appear, leading you through two steps. For a faster setup, you can select Add Sensor... in the context menu of a device to which you want to add the new sensor. This will skip the device selection and take you directly to step 2.

Step 1 - Select Device

Add Sensor Dialog

Add Sensor Dialog

Click here to enlarge: https://media-s3.paessler.com/prtg-screenshots/addsensor2_new.png

  • Select Add sensor to an existing device (default setting).
  • Choose the device you want to add the new sensor to.
  • Click Continue.

The Add Sensor dialog appears.

Step 2 - Choose Sensor Type

Add sensor assistant

Add sensor assistant

Click here to enlarge: https://media-s3.paessler.com/prtg-screenshots/addsensor3.png

The Add Sensor dialog helps you choose the correct sensor (see screenshot above).

  • Narrow down the sensor types:
      • Enter (parts of) the name into the search box. Alternative_A
      • Shortlist the sensor types by choosing appropriate criteria. Alternative_B
      • Go through the detailed list of sensors matching the selected device. Alternative_C
  • Choose which sensor best monitors the parameters you require.
  • Click the sensor box to select this sensor.

The sensor settings dialog opens.

  • Enter suitable sensor settings.

Note: PRTG suggests sensor types to create on the selected device. This recommendation is automatically calculated based on the current user's sensor usage and shows the ten most commonly used sensor types (if enough sensor types are already in use).

Note: If you are unsure which sensor type will provide the information you require, then we recommend that you use the filter categories to progressively narrow down your choices.

You can either:

  • Select the type of parameter you want to monitor via “monitor what". PN_1_gruen
  • Specify the type of target system you want to monitor and see what sensors are available for this type of hardware in “Target system type”. PN_2_gruen        
  • Choose the technology which you want to use for monitoring (for example SNMP or WMI) in “Technology used”. PN_3_gruen

Note: Please also consider whether a sensor’s performance impact is high Performance_bar_rot or low Performance_bar_gruen  by checking the bar in the lower left corner of the sensor box. For further information see the More section below.

  • Confirm via Continue.

PRTG will now create the sensor. The device's sensors list opens.

For more information about a sensor type, please see the manual section of the respective sensor (directly accessible via the “?”-symbol in the top-right corner). You can also go to the List of Available Sensor Types section to find a comprehensive overview of sensor types.

More

Knowledge Base: How can I change the number of entries in most used sensor types?

Knowledge Base: How to Speed Up PRTG (especially section 4 - Sensor Type and Monitoring Considerations)

 